HOME > >

  • SHL : Desiccant Air Dryer (Heatless Mini type) Desiccant Air Dryer
    Desiccant Air Dryer SHL : Desiccant Air Dryer (Heatless Mini type)

    ● Excellent condensate removal producing high quality compressed air under - 40℃ ● Adopting the activated alumina which has high mechanical strength and performance ● Easy installation and small installation space with box type ● Low energy consumption ● Silent operation with silencer ● Upon request for customer-engineered products    · High pressure    · Remote control, etc..

    기술자료 브로슈어 상세보기
    SHL : Desiccant Air Dryer (Heatless Mini type)
    (Heatless Mini type)
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서

    ● Excellent condensate removal producing high quality compressed air under - 40℃

    ● Adopting the activated alumina which has high mechanical strength and performance

    ● Easy installation and small installation space with box type

    ● Low energy consumption

    ● Silent operation with silencer

    ● Upon request for customer-engineered products
       · High pressure
       · Remote control, etc..

    Inlet pressure 7 kg/cm2

    Inlet temperature

    2℃ ~ 40℃
    Design pressure 9.9 kg/cm2 Ambient temperature 2℃ ~ 40℃
    Differential pressure 0.3 kg/cm2 Dew Point -40℃
     
    Model
    Flow Rate
    Compressor
    Applicable compressor
    Dimension [mm]
    Weight [kg]
    SHL-
    [Nm³/hr]
    [HP]
    [Fitting Hose]
    Width
    Length
    Height
    Absorbent
    All
    5
    8.5
    1
    3/8" PT
     
     
     
    500
    225
    745

    2.3

    23
    10
    17.0
    2 (2.5)
    3.2
    27
    15
    25.5
    3
    6.8
    36
    20
    34.0
    5
    11.0
    46
     

    NOTE
    1. The flow rate is based on 38℃ and 100PSIG.
    2. Bigger capacity models are available.
    3. The specification can be changed without notice to improve the products.

  • PHL : Desiccant Air Dryer (Heatless type) Desiccant Air Dryer
    Desiccant Air Dryer PHL : Desiccant Air Dryer (Heatless type)

    ● Excellent condensate removal producing high quality compressed air under - 60℃ ● Adopting the activated alumina which has high mechanical strength and performance ● Filter for inlet valve control air can prevent the malfunction of equipment ● Sequence control of Dehumidification/Regeneration/Repressurizing cycle (5min/10min) ● Heatless regeneration type ● Upon request for customer-engineered products    · Stainless steel vessel    · Terminal for dew point meter and demand control    · Various electric specification

    기술자료 브로슈어 상세보기
    PHL : Desiccant Air Dryer (Heatless type)
    (Heatless type)
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서

    ● Excellent condensate removal producing high quality compressed air under - 60℃

    ● Adopting the activated alumina which has high mechanical strength and performance

    ● Filter for inlet valve control air can prevent the malfunction of equipment

    ● Sequence control of Dehumidification/Regeneration/Repressurizing cycle (5min/10min)

    ● Heatless regeneration type

    ● Upon request for customer-engineered products
       · Stainless steel vessel
       · Terminal for dew point meter and demand control
       · Various electric specification

    Inlet pressure 7 kg/cm2

    Inlet temperature

    2℃ ~ 40℃
    Design pressure 9.9 kg/cm2 Ambient temperature 2℃ ~ 40℃
    Differential pressure 0.3 kg/cm2 Dew Point -40℃
     
     
    Model
    PHL-
    Flow Rate
    [Nm³/hr]
    Applicable
    compressor
    [HP]
    Dimension [mm]
    Connection
    Weight [kg]
    Length
    Width
    Height
    Absorbent
    All
    25
    43
    7
    840
    305
    960
    1/2" PT
    13
    60
    35
    60
    10
    840
    308
    1206
    3/4" PT
    18
    75
    50
    85
    15
    840
    310
    1515
    3/4" PT
    25
    100
    75
    128
    20
    840
    310
    2045
    3/4" PT
    38
    160
    100
    170
    20
    1150
    490
    1755
    1" PT
    50
    230
    125
    213
    25
    1150
    490
    1755
    1" PT
    57
    260
    150
    255
    30
    1150
    490
    1755
    1" PT
    63
    270
    175
    297
    35
    1150
    490
    1760
    1 1/2" PT
    75
    284
    200
    340
    45
    1150
    490
    1760
    1 1/2" PT
    87
    310
    250
    425
    50
    1270
    555
    1720
    1 1/2" PT
    124
    405
    350
    642
    75
    1270
    595
    1825
    1 1/2" PT
    174
    470
    500
    850
    100
    1400
    645
    2000
    2" PT
    248
    650
    650
    1105
    130
    1400
    700
    2130
    2" PT
    322
    720
    800
    1370
    150
    2100
    890
    2295
    3" FLG
    397
    900
    1000
    1700
    200
    2100
    890
    2295
    3" FLG
    496
    1130
    1200
    2040
    200
    2100
    890
    2295
    3" FLG
    595
    1300
    1400
    2380
    250
    2590
    1050
    2430
    3" FLG
    694
    1580
    1600
    2720
    300
    2590
    1050
    2430
    4" FLG
    798
    1760
    1800
    3060
    350
    2590
    1050
    2430
    4" FLG
    862
    1980
    2000
    3400
    400
    2590
    1050
    2430
    4" FLG
    998
    2200
    2250
    3825
    450
    2590
    1205
    2250
    4" FLG
    1123
    2480
    2500
    4250
    500
    2590
    1205
    2250
    4" FLG
    1248
    2700
    2750
    4675
    550
    2590
    1205
    2490
    4" FLG
    1361
    2970
    3000
    5100
    600
    2590
    1205
    2975
    6" FLG
    1497
    3240
    3500
    5950
    680
    3100
    1280
    3400
    6" FLG
    1747
    3830
    4000
    6800
    750
    3100
    1360
    3215
    6" FLG
    1996
    4410
     

    NOTE
    1. The flowrate is based on 38℃ and 100PSIG.
    2. Bigger capacity models are available.
    3. The specification can be changed without notice to improve the products.

  • PIH : Desiccant Air Dryer Desiccant Air Dryer
    Desiccant Air Dryer PIH : Desiccant Air Dryer

    ● Excellent condensate removal producing high quality compressed air under - 60℃ ● Adopting the activated alumina which has high mechanical strength and performance ● Filter for inlet valve control air can prevent the equipment malfunction ● Sequence control of dehumidifying/regeneration/repressurization cycle (5min/10min) ● Additional heat is not necessary for dry air regenaration ● Upon request for customer-engineered products    · Stainless steel vessel    · Terminal for dew point meter and demand control    · Various electric specification

    기술자료 브로슈어 상세보기
    PIH : Desiccant Air Dryer
    (Internal Heater type)
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서

    ● Excellent condensate removal producing high quality compressed air under - 60℃

    ● Adopting the activated alumina which has high mechanical strength and performance

    ● Filter for inlet valve control air can prevent the equipment malfunction

    ● Sequence control of dehumidifying/regeneration/repressurization cycle (5min/10min)

    ● Additional heat is not necessary for dry air regenaration

    ● Upon request for customer-engineered products
       · Stainless steel vessel
       · Terminal for dew point meter and demand control
       · Various electric specification

     
    Inlet pressure 7 kg/cm2

    Inlet temperature

    2℃ ~ 40℃
    Design pressure 9.9 kg/cm2 Ambient temperature 2℃ ~ 40℃
    Differential pressure 0.3 kg/cm2 Dew Point -40℃
     
    Model
    PIH-
    Flow Rate 
    [Nm³/hr]

    Connection

    Heater
    [kw]
    Dimension [mm]
    Blower
    [kg]
    Weight
    [kg]
    Width
    Length
    Height
    100 150 25A 2.7
    870
    870
    2300
    -
    300
    150 250 40A 3.0
    970
    970
    2350
    -
    450
    200 370 40A 4.0
    1070
    1070
    2400
    -
    680
    285 495 40A 5.0
    1070
    1070
    2450
    -
    850
    350 660 50A 7.0
    1150
    1150
    2450
    -
    1000
    430 870 50A 8.0
    1150
    1150
    2450
    -
    1100
    560 1050 65A 10.0
    1260
    1260
    2450
    -
    1430
    720 1380 65A 12.0
    1350
    1600
    2500
    -
    1650
    900 1680 80A 16.0
    1450
    1800
    2550
    -
    2000
    1100 1950 80A 18.0
    1450
    1800
    2550
    -
    2400
    1350 2280 80A 24.0
    1900
    1880
    2600
    -
    2900
    1550 2950 100A 26.0
    2430
    2000
    2600
    -
    3300
    2100 3700 100A 36.0
    2430
    2000
    2700
    -
    4500
    3000 5400 150A 52.0
    2800
    2100
    2750
    -
    5500
     

    NOTE
    1. The flow rate is based on 38℃ and 100PSIG.
    2. Bigger capacity models are available.
    3. The specification can be changed without notice to improve the products.

  • PEH : Desiccant Air Dryer (External Heater type) Desiccant Air Dryer
    Desiccant Air Dryer PEH : Desiccant Air Dryer (External Heater type)

    ● Excellent condensate removal producing high quality compressed air under - 40℃ ● Adopting the activated alumina which has high mechanical strength and performance ● Automatically bock the purge air in case the line pressure drops ● Easy to check valve malfunction and the leak from the purge pressure control switch ● Energy saving with auxiliary heater ● Filter for inlet valve control air can prevent the equipment malfunction ● Purge air loss volume is minimized with the external heater ● Life time of activated alumina is long because the alumina is not contacted directly to heater ● Long life with low density heater ● Upon request for customer-engineered products    · Stainless steel vessel    · Terminal for dew point meter and demand control    · Various electric specification

    기술자료 브로슈어 상세보기
    PEH : Desiccant Air Dryer (External Heater type)
    (External Heater type)
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서

    ● Excellent condensate removal producing high quality compressed air under - 40℃

    ● Adopting the activated alumina which has high mechanical strength and performance

    ● Automatically bock the purge air in case the line pressure drops

    ● Easy to check valve malfunction and the leak from the purge pressure control switch

    ● Energy saving with auxiliary heater

    ● Filter for inlet valve control air can prevent the equipment malfunction

    ● Purge air loss volume is minimized with the external heater

    ● Life time of activated alumina is long because the alumina is not contacted directly to heater

    ● Long life with low density heater

    ● Upon request for customer-engineered products
       · Stainless steel vessel
       · Terminal for dew point meter and demand control
       · Various electric specification

     

    Inlet pressure 7 kg/cm2

    Inlet temperature

    2℃ ~ 40℃
    Design pressure 9.9 kg/cm2 Ambient temperature 2℃ ~ 40℃
    Differential pressure 0.3 kg/cm2 Dew Point -40℃
     
    Model
    PEH-
    Flow Rate
    [Nm³/hr]

    Connection

    Heater
    [kw]
    Dimension [mm]
    Absorbent
    [kg]
    Weight
    [kg]
    Length
    Width
    Height
    100
    150
    25A
    2.1
    870
    870
    2300
    90
    300
    150
    250
    40A
    2.4
    970
    970
    2300
    110
    450
    200
    370
    40A
    3.6
    1000
    1000
    2100
    150
    600
    285
    495
    40A
    4.0
    1000
    1000
    2100
    210
    750
    350
    660
    50A
    6.0
    1150
    1150
    2450
    250
    900
    430
    870
    50A
    7.5
    1150
    1150
    2450
    300
    1000
    560
    1050
    65A

    9.0

    1500
    1500
    2700
    390
    1300
    720
    1380
    65A
    11.0
    1450
    1450
    2600
    520
    1500
    900
    1680
    80A
    13.5
    1600
    1500
    2700
    630
    1800
    1100
    1950
    80A
    15.0
    1600
    1500
    2700
    770
    2200
    1350
    2280
    80A
    18.0
    1900
    1900
    2700
    950
    2600
    1550
    2950
    100A
    30.0
    1900
    1900
    2700
    1050
    3000
    2100
    3700
    100A
    33.0
    2400
    1700
    3100
    1470
    4200
    3000
    5400
    125A
    46.0
    2600
    2000
    2860
    2100
    5200
    4100
    6600
    150A
    56.0
    2800
    1800
    3000
    2900
    6000
    5400
    8500
    150A
    70.0
    3000
    2000
    3000
    3780
    6800
    6000
    10500
    200A
    85.0
    3200
    2300
    3000
    4200
    7500
    7000
    12000
    200A
    100.0
    3500
    2300
    3100
    4900
    9000
    9000
    15000
    250A
    130.0
    3900
    2300
    3200
    6500
    10000
     

    NOTE
    1. The flow rate is based on 38℃ and 100PSIG.
    2. Bigger capacity models are available.
    3. The specification can be changed without notice to improve the products.

  • PEHB : Desiccant Air Dryer Desiccant Air Dryer
    Desiccant Air Dryer PEHB : Desiccant Air Dryer

    ● Excellent condensate removal producing high quality compressed air under - 40℃ ● Adopting the activated alumina which has high mechanical strength and performance ● Automatically bock the purge air in case the line pressure drops ● Easy to check valve malfunction and the leak from the purge pressure control switch ● Energy saving with auxiliary heater ● Filter for inlet valve control air can prevent the equipment malfunction ● Using outside air for regeneration ● Energy saving design (Very low purge air loss) ● Low noise and low trouble with high-performance two stage ring blower ● Long life with low density heater ● Upon request for customer-engineered products    · Stainless steel vessel    · Terminal for dew point meter and demand control    · Various electric specification

    기술자료 브로슈어 상세보기
    PEHB : Desiccant Air Dryer
    Desiccant Air Dryer
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서

    ● Excellent condensate removal producing high quality compressed air under - 40℃

    ● Adopting the activated alumina which has high mechanical strength and performance

    ● Automatically bock the purge air in case the line pressure drops

    ● Easy to check valve malfunction and the leak from the purge pressure control switch

    ● Energy saving with auxiliary heater

    ● Filter for inlet valve control air can prevent the equipment malfunction

    ● Using outside air for regeneration

    ● Energy saving design (Very low purge air loss)

    ● Low noise and low trouble with high-performance two stage ring blower

    ● Long life with low density heater

    ● Upon request for customer-engineered products
       · Stainless steel vessel
       · Terminal for dew point meter and demand control
       · Various electric specification

      7 kg/cm2

    Inlet temperature

    2℃ ~ 40℃
    Design pressure 9.9 kg/cm2 Ambient temperature 2℃ ~ 40℃
    Differential pressure 0.3 kg/cm2 Dew Point -40℃
     
     
     
     
     
    Model
    PEHB-
    Flow Rate 
    [Nm³/hr]

    Connection

    Heater
    [kw]
    Absorbent
    [kw]
    Dimension [mm]
    Weight[kg]
    Width
    Length
    Height
    150 250 40A 4.0 1.5 1070 900 2400 500
    250 370 40A 5.0 1.9 1150 900 2400 650
    285 495 40A 7.5 2.2 1150 1000 2450 900
    350 660 50A 11.0 3.0 1260 1000 2460 1000
    430 870 50A 13.0 3.7 1350 1000 2460 1200
    560 1050 65A 15.0 3.7 1260 1600 2430 1500
    720 1380 65A 21.0 4.5 1600 1600 2450 1800
    900 1680 80A 24.0 6.0 2400 1700 2550 2000
    1100 1950 80A 30.0 7.5 2500 1800 2550 2400
    1350 2280 80A 34.0 7.5 2800 2000 3000 2900
    1550 2950 100A 42.0 9.0 3000 2200 3000 3400
    2100 3700 100A 55.0 11.2 3000 2200 3000 4000
    3000 5400 125A 86.0 15.0 3100 2200 3000 4800
    4100 6600 150A 100.0 18.5 3200 2300 3000 6000
    5400 8500 150A 140.0 30.0 3200 2500 3000 7300
    6000 10500 200A 160.0 30.0 3400 2500 3000 8100
    7000 12000 200A 180.0 37.5 3600 2500 3000 10300
    9000 15000 250A 220.0 45.0 4000 3000 3000 12300
     
     

    NOTE

    1. The flow rate is based on 38℃ and 100PSIG.
    2. Bigger capacity models are available.
    3. The specification can be changed without notice to improve the products.