HOME > >

  • HYD : Refrigerated Air Dryer (Air-cooled type) Refrigerated Air Dryer Refrigerated Air Dryer Refrigerated Air Dryer
    Refrigerated Air Dryer Refrigerated Air Dryer Refrigerated Air Dryer HYD : Refrigerated Air Dryer (Air-cooled type)

    1. Heat exchanger in aluminum    - Lighter weight    - Dew point is excellent with excellent heat transmission and larger heat exchanging area    - The possibility of internal crack is low with one matarial heat exchanger.    - Corrosion resistant with oxidization film   2. Indicating correct dew point with detecting the temperature of compressed air instead of refrigerant   3. High quality PCB controller   4. Max. operating pressure : 14bar   5. You can open and close conveniently the canopy with the one-tough locker.   6. Adopting timer-controlled drain valve with Viton O-ring   7. Upon request for customer-engineered products    - Adding control devices and output signa    - R404, R407 refrigerant    - Various electric specification

    기술자료 브로슈어 상세보기
    HYD : Refrigerated Air Dryer (Air-cooled type)
    (Air Cooled Type)
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서
    1. Heat exchanger in aluminum
       - Lighter weight
       - Dew point is excellent with excellent heat transmission and larger heat exchanging area
       - The possibility of internal crack is low with one matarial heat exchanger.
       - Corrosion resistant with oxidization film
     
    2. Indicating correct dew point with detecting the temperature of compressed air instead of refrigerant
     
    3. High quality PCB controller
     
    4. Max. operating pressure : 14bar
     
    5. You can open and close conveniently the canopy with the one-tough locker.
     
    6. Adopting timer-controlled drain valve with Viton O-ring
     
    7. Upon request for customer-engineered products
       - Adding control devices and output signa
       - R404, R407 refrigerant
       - Various electric specification
    Inlet pressure 7 kg/cm2 
    Max. inlet temperature
    40℃
    Design pressure 14 kg/cm2  Ambient temperature 2℃ ~ 40℃
    Differential pressure 0.2 kg/cm2 Pressure Dew Point 2℃ ~ 8℃
     


     
    Model
    Flow Rate
    Power supply  Refrigerant compressor 
    Connection
    Dimension [mm]
    Weight
    HYD-
    [Nm³/min]
    V-Ph-Hz  [HP]
    Width
    Length
    Height
    [kg]
    5N
    0.65
    220-1-60  1/4
    G 1/2"
    358
    468
    712
    36
    7N
    0.98
    1/4
    G 1/2"
    358
    468
    712
    36
    10N
    1.40
    1/3
    G 1/2"
    358
    468
    712
    36
    15N
    1.90
    1/3
    G 1"
    428
    508
    709 
     
    45 
    20N
    2.65
    1/3
    G 1"
    428
    508
    709
    45
    30N
    3.90
    3/4
    G 1"
    358
    658
    864
    66
    35N
    4.70
    3/4
    G 1"
    358
    658
    864
    66
    50N
    6.70
    1
    G 1-1/2"
    408
    708
    952
    89
    75N
    10.50
    11/2
    G 2"
    458
    798
    1045 
    120
    100N
    14.20
    2
    G 2"
    458
    858
    1145
    126
    130N
    18.0
    3
    G 2-1/2"
    560
    1010
    1330 
    167
    150N
    21
    3
    G 2-1/2"
    560
    1010
    1330
    172
    170N  24 4  FLG 65A 690  1210  1323  230 
    200N  30  4  FLG 80A 690  1210  1323  250 
    250N  39  5 FLG 80A 800  1300  1400  350 
    300N   47 5 FLG 100A 800 1300 1400 400
    400N   56 10  FLG 100A 1200  1500  1700  650 
    500N  66 15 FLG 150A 1200 1850  1700  750 
    600N 85   15 FLG 150A 1200  1850  1700  850
     
     
    NOTE
     
    1. Refrigerant R-134, R-22, R-404, R-407 and R410 available.
       (R-134 is used for HYD-20N and smaller model, R-404 or R-407 is used for the others)
     
    2. The other electric power products are available.
       (Single phase on models HYD-75N and below.  The above is 3 phase.)
     
    3. Above flow rate is based on 60Hz.
     
    4. Bigger model than the above is available.
     
    5. The specification can be changed without notice to improve the products.
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
  • HYD-W : Refrigerated Air Dryer(Water Cooled type) Refrigerated Air Dryer Refrigerated Air Dryer Refrigerated Air Dryer
    Refrigerated Air Dryer Refrigerated Air Dryer Refrigerated Air Dryer HYD-W : Refrigerated Air Dryer(Water Cooled type)

    1. The panel monitor displays the various temperatures (on model of HYD-170W and above)   2. IP54 Class Axial fan (Waterproof)   3. The power drain (HAD-100) can drain the condensate from heat exchanger properly   4. Upon request for customer-engineered products – for high pressure (9.9kg/cm2 above), Stainless steel material heat exchanger – Adding control devices and output signal – R404, R407 refrigerant – Various electric specification

    기술자료 브로슈어 상세보기
    HYD-W : Refrigerated Air Dryer(Water Cooled type)
    (Water Cooled type)
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서
    1. The panel monitor displays the various temperatures (on model of HYD-170W and above)
     
    2. IP54 Class Axial fan (Waterproof)
     
    3. The power drain (HAD-100) can drain the condensate from heat exchanger properly
     
    4. Upon request for customer-engineered products
    – for high pressure (9.9kg/cm2 above), Stainless steel material heat exchanger
    – Adding control devices and output signal
    – R404, R407 refrigerant
    – Various electric specification
    Differential pressure 0.2 kg/cm2
    Max. working pressure
     9.9 kg/cm2
    Inlet temperature 2℃ ~ 40℃ Cooling water temperature 25℃ ~ 35℃
    Ambient temperature 2℃ ~ 40℃ Dew Point 4℃ ~ 10℃
     
    Model
    Flow Rate
    Connection
    Dimension [mm]
    Weight
    HYD-
    [Nm³/min]
    Width
    Length
    Height
    [kg]
    130W
    19.5
    65A
    1,150
    620
    1,200
    170
    150W
    22.5
    65A
    1,150
    620
    1,200
    200
    170W
    25.7
    65A
    1,200
    700
    1,270
    320
    200W
    32.1
    80A
    1,200
    700
    1,270
    350
    250W
    41.7
    80A
    1,350
    770
    1,360
    450
    300W
    50.3
    100A
    1,350
    770
    1,360
    550
    400W
    59.9
    100A
    1,600
    1,150
    1,700
    650
    500W
    70.6
    150A
    1,600
    1,150
    1,700
    780
    600W
    91.0
    150A
    1,600
    1,150
    1,700
    780
    750W
    120.0
    200A
    1,800
    1,400
    1,750
    950
    900W
    140.0
    200A
    1,800
    1,400
    1,750
    1,010
    1200W
    180.0
    200A
    2,000
    1,400
    1,800
    1,300
     
    NOTE
    1. Refrigerant : R134, R22, R404, R407, R410 available.
    2. 3Phase for all. Upon request for customer-engineered products.
    3. Above flow rate is based on 60Hz.
    4. High pressure product is also available.
    5. Bigger model than HYD-1200W is available.
    6. The specification can be changed without notice to improve the products.
  • HYD-HT : Refrigerated Air Dryer(High inlet temp) Refrigerated Air Dryer Refrigerated Air Dryer Refrigerated Air Dryer
    Refrigerated Air Dryer Refrigerated Air Dryer Refrigerated Air Dryer HYD-HT : Refrigerated Air Dryer(High inlet temp)

    1. High performance heat exchanger can remove the condensate properly in the compressed air.   2. The automatic temperature sensor in the built-in cooler can prevent the freeze and save the energy.   3. The built-in after-cooler and filter can save installation space.   4. The built-in pre-filter and line-filter can improve the air quality.   5. You can open and close conveniently the canopy with the one-tough locker.   6. The built-in after-cooler allows max. 80℃ inlet compressed air.   7. Upon request for customer-engineered products    - for high pressure (9.9kg/cm2 above)    - Stainless steel material heat exchanger    - Adding control devices and output signal    - R404, R407 refrigerant    - Various electric specification

    기술자료 브로슈어 상세보기
    HYD-HT : Refrigerated Air Dryer(High inlet temp)
    (for High Temperature)
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서
    1. High performance heat exchanger can remove the condensate properly in the compressed air.
     
    2. The automatic temperature sensor in the built-in cooler can prevent the freeze and save the energy.
     
    3. The built-in after-cooler and filter can save installation space.
     
    4. The built-in pre-filter and line-filter can improve the air quality.
     
    5. You can open and close conveniently the canopy with the one-tough locker.
     
    6. The built-in after-cooler allows max. 80℃ inlet compressed air.
     
    7. Upon request for customer-engineered products
       - for high pressure (9.9kg/cm2 above)
       - Stainless steel material heat exchanger
       - Adding control devices and output signal
       - R404, R407 refrigerant
       - Various electric specification
     
    Inlet pressure 7 kg/cm2 Max. inlet temperature 80℃
    Design pressure 9.9 kg/cm2 Ambient temperature 2℃ ~ 40℃
    Differential pressure 0.3 kg/cm2 Dew Point 4℃ ~ 10℃
     
    Model Flow Rate Built-in filter Refrigerant compressor Connection Dimension [mm] Weight
    HYD- [Nm³/min] [㎛] [HP] Width Length Height [kg]
    5HT
    0.65
    5, 1
    1/4
    15A
    455
    625
    860
    60
    7HT
    0.98
    5, 1
    1/4
    15A
    455
    625
    860
    60
    10HT
    1.40
    5, 1
    1/4
    25A
    455
    625
    900
    65
    15HT
    1.90
    5, 1
    1/3
    25A
    455
    625
    950
    80
    20HT
    2.65
    5, 1
    1/3
    25A
    455
    625
    950
    80
    30HT
    3.90
    5, 1
    3/4
    25A
    530
    730
    1135
    105
    50HT
    6.70
    5
    1
    40A
    1005
    455
    1577
    130
    75HT
    10.50
    5
    1 1/2
    50A
    1095
    455
    1625
    220
    100HT
    14.20
    5
    2
    50A
    1255
    525
    1687
    245
     
    NOTE
    1. Refrigerant : R134, R22, R404, R407, R410 available.
    2. Upon request for customer-engineered products.
    3. Above flow rate is based on 60Hz.
    4. High pressure product is also available.
    5. Bigger model than HYD-100HT is available.
    6. The specification can be changed without notice to improve the products.
  • SHL : Desiccant Air Dryer (Heatless Mini type) Desiccant Air Dryer
    Desiccant Air Dryer SHL : Desiccant Air Dryer (Heatless Mini type)

    ● Excellent condensate removal producing high quality compressed air under - 40℃ ● Adopting the activated alumina which has high mechanical strength and performance ● Easy installation and small installation space with box type ● Low energy consumption ● Silent operation with silencer ● Upon request for customer-engineered products    · High pressure    · Remote control, etc..

    기술자료 브로슈어 상세보기
    SHL : Desiccant Air Dryer (Heatless Mini type)
    (Heatless Mini type)
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서

    ● Excellent condensate removal producing high quality compressed air under - 40℃

    ● Adopting the activated alumina which has high mechanical strength and performance

    ● Easy installation and small installation space with box type

    ● Low energy consumption

    ● Silent operation with silencer

    ● Upon request for customer-engineered products
       · High pressure
       · Remote control, etc..

    Inlet pressure 7 kg/cm2

    Inlet temperature

    2℃ ~ 40℃
    Design pressure 9.9 kg/cm2 Ambient temperature 2℃ ~ 40℃
    Differential pressure 0.3 kg/cm2 Dew Point -40℃
     
    Model
    Flow Rate
    Compressor
    Applicable compressor
    Dimension [mm]
    Weight [kg]
    SHL-
    [Nm³/hr]
    [HP]
    [Fitting Hose]
    Width
    Length
    Height
    Absorbent
    All
    5
    8.5
    1
    3/8" PT
     
     
     
    500
    225
    745

    2.3

    23
    10
    17.0
    2 (2.5)
    3.2
    27
    15
    25.5
    3
    6.8
    36
    20
    34.0
    5
    11.0
    46
     

    NOTE
    1. The flow rate is based on 38℃ and 100PSIG.
    2. Bigger capacity models are available.
    3. The specification can be changed without notice to improve the products.

  • PHL : Desiccant Air Dryer (Heatless type) Desiccant Air Dryer
    Desiccant Air Dryer PHL : Desiccant Air Dryer (Heatless type)

    ● Excellent condensate removal producing high quality compressed air under - 60℃ ● Adopting the activated alumina which has high mechanical strength and performance ● Filter for inlet valve control air can prevent the malfunction of equipment ● Sequence control of Dehumidification/Regeneration/Repressurizing cycle (5min/10min) ● Heatless regeneration type ● Upon request for customer-engineered products    · Stainless steel vessel    · Terminal for dew point meter and demand control    · Various electric specification

    기술자료 브로슈어 상세보기
    PHL : Desiccant Air Dryer (Heatless type)
    (Heatless type)
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서

    ● Excellent condensate removal producing high quality compressed air under - 60℃

    ● Adopting the activated alumina which has high mechanical strength and performance

    ● Filter for inlet valve control air can prevent the malfunction of equipment

    ● Sequence control of Dehumidification/Regeneration/Repressurizing cycle (5min/10min)

    ● Heatless regeneration type

    ● Upon request for customer-engineered products
       · Stainless steel vessel
       · Terminal for dew point meter and demand control
       · Various electric specification

    Inlet pressure 7 kg/cm2

    Inlet temperature

    2℃ ~ 40℃
    Design pressure 9.9 kg/cm2 Ambient temperature 2℃ ~ 40℃
    Differential pressure 0.3 kg/cm2 Dew Point -40℃
     
     
    Model
    PHL-
    Flow Rate
    [Nm³/hr]
    Applicable
    compressor
    [HP]
    Dimension [mm]
    Connection
    Weight [kg]
    Length
    Width
    Height
    Absorbent
    All
    25
    43
    7
    840
    305
    960
    1/2" PT
    13
    60
    35
    60
    10
    840
    308
    1206
    3/4" PT
    18
    75
    50
    85
    15
    840
    310
    1515
    3/4" PT
    25
    100
    75
    128
    20
    840
    310
    2045
    3/4" PT
    38
    160
    100
    170
    20
    1150
    490
    1755
    1" PT
    50
    230
    125
    213
    25
    1150
    490
    1755
    1" PT
    57
    260
    150
    255
    30
    1150
    490
    1755
    1" PT
    63
    270
    175
    297
    35
    1150
    490
    1760
    1 1/2" PT
    75
    284
    200
    340
    45
    1150
    490
    1760
    1 1/2" PT
    87
    310
    250
    425
    50
    1270
    555
    1720
    1 1/2" PT
    124
    405
    350
    642
    75
    1270
    595
    1825
    1 1/2" PT
    174
    470
    500
    850
    100
    1400
    645
    2000
    2" PT
    248
    650
    650
    1105
    130
    1400
    700
    2130
    2" PT
    322
    720
    800
    1370
    150
    2100
    890
    2295
    3" FLG
    397
    900
    1000
    1700
    200
    2100
    890
    2295
    3" FLG
    496
    1130
    1200
    2040
    200
    2100
    890
    2295
    3" FLG
    595
    1300
    1400
    2380
    250
    2590
    1050
    2430
    3" FLG
    694
    1580
    1600
    2720
    300
    2590
    1050
    2430
    4" FLG
    798
    1760
    1800
    3060
    350
    2590
    1050
    2430
    4" FLG
    862
    1980
    2000
    3400
    400
    2590
    1050
    2430
    4" FLG
    998
    2200
    2250
    3825
    450
    2590
    1205
    2250
    4" FLG
    1123
    2480
    2500
    4250
    500
    2590
    1205
    2250
    4" FLG
    1248
    2700
    2750
    4675
    550
    2590
    1205
    2490
    4" FLG
    1361
    2970
    3000
    5100
    600
    2590
    1205
    2975
    6" FLG
    1497
    3240
    3500
    5950
    680
    3100
    1280
    3400
    6" FLG
    1747
    3830
    4000
    6800
    750
    3100
    1360
    3215
    6" FLG
    1996
    4410
     

    NOTE
    1. The flowrate is based on 38℃ and 100PSIG.
    2. Bigger capacity models are available.
    3. The specification can be changed without notice to improve the products.

  • PIH : Desiccant Air Dryer Desiccant Air Dryer
    Desiccant Air Dryer PIH : Desiccant Air Dryer

    ● Excellent condensate removal producing high quality compressed air under - 60℃ ● Adopting the activated alumina which has high mechanical strength and performance ● Filter for inlet valve control air can prevent the equipment malfunction ● Sequence control of dehumidifying/regeneration/repressurization cycle (5min/10min) ● Additional heat is not necessary for dry air regenaration ● Upon request for customer-engineered products    · Stainless steel vessel    · Terminal for dew point meter and demand control    · Various electric specification

    기술자료 브로슈어 상세보기
    PIH : Desiccant Air Dryer
    (Internal Heater type)
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서

    ● Excellent condensate removal producing high quality compressed air under - 60℃

    ● Adopting the activated alumina which has high mechanical strength and performance

    ● Filter for inlet valve control air can prevent the equipment malfunction

    ● Sequence control of dehumidifying/regeneration/repressurization cycle (5min/10min)

    ● Additional heat is not necessary for dry air regenaration

    ● Upon request for customer-engineered products
       · Stainless steel vessel
       · Terminal for dew point meter and demand control
       · Various electric specification

     
    Inlet pressure 7 kg/cm2

    Inlet temperature

    2℃ ~ 40℃
    Design pressure 9.9 kg/cm2 Ambient temperature 2℃ ~ 40℃
    Differential pressure 0.3 kg/cm2 Dew Point -40℃
     
    Model
    PIH-
    Flow Rate 
    [Nm³/hr]

    Connection

    Heater
    [kw]
    Dimension [mm]
    Blower
    [kg]
    Weight
    [kg]
    Width
    Length
    Height
    100 150 25A 2.7
    870
    870
    2300
    -
    300
    150 250 40A 3.0
    970
    970
    2350
    -
    450
    200 370 40A 4.0
    1070
    1070
    2400
    -
    680
    285 495 40A 5.0
    1070
    1070
    2450
    -
    850
    350 660 50A 7.0
    1150
    1150
    2450
    -
    1000
    430 870 50A 8.0
    1150
    1150
    2450
    -
    1100
    560 1050 65A 10.0
    1260
    1260
    2450
    -
    1430
    720 1380 65A 12.0
    1350
    1600
    2500
    -
    1650
    900 1680 80A 16.0
    1450
    1800
    2550
    -
    2000
    1100 1950 80A 18.0
    1450
    1800
    2550
    -
    2400
    1350 2280 80A 24.0
    1900
    1880
    2600
    -
    2900
    1550 2950 100A 26.0
    2430
    2000
    2600
    -
    3300
    2100 3700 100A 36.0
    2430
    2000
    2700
    -
    4500
    3000 5400 150A 52.0
    2800
    2100
    2750
    -
    5500
     

    NOTE
    1. The flow rate is based on 38℃ and 100PSIG.
    2. Bigger capacity models are available.
    3. The specification can be changed without notice to improve the products.

  • PEH : Desiccant Air Dryer (External Heater type) Desiccant Air Dryer
    Desiccant Air Dryer PEH : Desiccant Air Dryer (External Heater type)

    ● Excellent condensate removal producing high quality compressed air under - 40℃ ● Adopting the activated alumina which has high mechanical strength and performance ● Automatically bock the purge air in case the line pressure drops ● Easy to check valve malfunction and the leak from the purge pressure control switch ● Energy saving with auxiliary heater ● Filter for inlet valve control air can prevent the equipment malfunction ● Purge air loss volume is minimized with the external heater ● Life time of activated alumina is long because the alumina is not contacted directly to heater ● Long life with low density heater ● Upon request for customer-engineered products    · Stainless steel vessel    · Terminal for dew point meter and demand control    · Various electric specification

    기술자료 브로슈어 상세보기
    PEH : Desiccant Air Dryer (External Heater type)
    (External Heater type)
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서

    ● Excellent condensate removal producing high quality compressed air under - 40℃

    ● Adopting the activated alumina which has high mechanical strength and performance

    ● Automatically bock the purge air in case the line pressure drops

    ● Easy to check valve malfunction and the leak from the purge pressure control switch

    ● Energy saving with auxiliary heater

    ● Filter for inlet valve control air can prevent the equipment malfunction

    ● Purge air loss volume is minimized with the external heater

    ● Life time of activated alumina is long because the alumina is not contacted directly to heater

    ● Long life with low density heater

    ● Upon request for customer-engineered products
       · Stainless steel vessel
       · Terminal for dew point meter and demand control
       · Various electric specification

     

    Inlet pressure 7 kg/cm2

    Inlet temperature

    2℃ ~ 40℃
    Design pressure 9.9 kg/cm2 Ambient temperature 2℃ ~ 40℃
    Differential pressure 0.3 kg/cm2 Dew Point -40℃
     
    Model
    PEH-
    Flow Rate
    [Nm³/hr]

    Connection

    Heater
    [kw]
    Dimension [mm]
    Absorbent
    [kg]
    Weight
    [kg]
    Length
    Width
    Height
    100
    150
    25A
    2.1
    870
    870
    2300
    90
    300
    150
    250
    40A
    2.4
    970
    970
    2300
    110
    450
    200
    370
    40A
    3.6
    1000
    1000
    2100
    150
    600
    285
    495
    40A
    4.0
    1000
    1000
    2100
    210
    750
    350
    660
    50A
    6.0
    1150
    1150
    2450
    250
    900
    430
    870
    50A
    7.5
    1150
    1150
    2450
    300
    1000
    560
    1050
    65A

    9.0

    1500
    1500
    2700
    390
    1300
    720
    1380
    65A
    11.0
    1450
    1450
    2600
    520
    1500
    900
    1680
    80A
    13.5
    1600
    1500
    2700
    630
    1800
    1100
    1950
    80A
    15.0
    1600
    1500
    2700
    770
    2200
    1350
    2280
    80A
    18.0
    1900
    1900
    2700
    950
    2600
    1550
    2950
    100A
    30.0
    1900
    1900
    2700
    1050
    3000
    2100
    3700
    100A
    33.0
    2400
    1700
    3100
    1470
    4200
    3000
    5400
    125A
    46.0
    2600
    2000
    2860
    2100
    5200
    4100
    6600
    150A
    56.0
    2800
    1800
    3000
    2900
    6000
    5400
    8500
    150A
    70.0
    3000
    2000
    3000
    3780
    6800
    6000
    10500
    200A
    85.0
    3200
    2300
    3000
    4200
    7500
    7000
    12000
    200A
    100.0
    3500
    2300
    3100
    4900
    9000
    9000
    15000
    250A
    130.0
    3900
    2300
    3200
    6500
    10000
     

    NOTE
    1. The flow rate is based on 38℃ and 100PSIG.
    2. Bigger capacity models are available.
    3. The specification can be changed without notice to improve the products.

  • PEHB : Desiccant Air Dryer Desiccant Air Dryer
    Desiccant Air Dryer PEHB : Desiccant Air Dryer

    ● Excellent condensate removal producing high quality compressed air under - 40℃ ● Adopting the activated alumina which has high mechanical strength and performance ● Automatically bock the purge air in case the line pressure drops ● Easy to check valve malfunction and the leak from the purge pressure control switch ● Energy saving with auxiliary heater ● Filter for inlet valve control air can prevent the equipment malfunction ● Using outside air for regeneration ● Energy saving design (Very low purge air loss) ● Low noise and low trouble with high-performance two stage ring blower ● Long life with low density heater ● Upon request for customer-engineered products    · Stainless steel vessel    · Terminal for dew point meter and demand control    · Various electric specification

    기술자료 브로슈어 상세보기
    PEHB : Desiccant Air Dryer
    Desiccant Air Dryer
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서

    ● Excellent condensate removal producing high quality compressed air under - 40℃

    ● Adopting the activated alumina which has high mechanical strength and performance

    ● Automatically bock the purge air in case the line pressure drops

    ● Easy to check valve malfunction and the leak from the purge pressure control switch

    ● Energy saving with auxiliary heater

    ● Filter for inlet valve control air can prevent the equipment malfunction

    ● Using outside air for regeneration

    ● Energy saving design (Very low purge air loss)

    ● Low noise and low trouble with high-performance two stage ring blower

    ● Long life with low density heater

    ● Upon request for customer-engineered products
       · Stainless steel vessel
       · Terminal for dew point meter and demand control
       · Various electric specification

      7 kg/cm2

    Inlet temperature

    2℃ ~ 40℃
    Design pressure 9.9 kg/cm2 Ambient temperature 2℃ ~ 40℃
    Differential pressure 0.3 kg/cm2 Dew Point -40℃
     
     
     
     
     
    Model
    PEHB-
    Flow Rate 
    [Nm³/hr]

    Connection

    Heater
    [kw]
    Absorbent
    [kw]
    Dimension [mm]
    Weight[kg]
    Width
    Length
    Height
    150 250 40A 4.0 1.5 1070 900 2400 500
    250 370 40A 5.0 1.9 1150 900 2400 650
    285 495 40A 7.5 2.2 1150 1000 2450 900
    350 660 50A 11.0 3.0 1260 1000 2460 1000
    430 870 50A 13.0 3.7 1350 1000 2460 1200
    560 1050 65A 15.0 3.7 1260 1600 2430 1500
    720 1380 65A 21.0 4.5 1600 1600 2450 1800
    900 1680 80A 24.0 6.0 2400 1700 2550 2000
    1100 1950 80A 30.0 7.5 2500 1800 2550 2400
    1350 2280 80A 34.0 7.5 2800 2000 3000 2900
    1550 2950 100A 42.0 9.0 3000 2200 3000 3400
    2100 3700 100A 55.0 11.2 3000 2200 3000 4000
    3000 5400 125A 86.0 15.0 3100 2200 3000 4800
    4100 6600 150A 100.0 18.5 3200 2300 3000 6000
    5400 8500 150A 140.0 30.0 3200 2500 3000 7300
    6000 10500 200A 160.0 30.0 3400 2500 3000 8100
    7000 12000 200A 180.0 37.5 3600 2500 3000 10300
    9000 15000 250A 220.0 45.0 4000 3000 3000 12300
     
     

    NOTE

    1. The flow rate is based on 38℃ and 100PSIG.
    2. Bigger capacity models are available.
    3. The specification can be changed without notice to improve the products.

     

  • PMD : Membrane Air Dryer Membrane Air Dryer
    Membrane Air Dryer PMD : Membrane Air Dryer

    ● Installed in the end of the compressed air system, it can produce 20℃ dew-point high quality compressed air ● You can install it on the wall easily with bracket ● No electric consumption, no power, no noise ● Environmentally friendly ● Beautiful appearance with aluminum anodized housing ● Easily control the purge air with needle valve (0% ~) ● Upon request for customer-engineered products ● You can use it permanently if the oil is removed beforehand properly

    기술자료 브로슈어 상세보기
    PMD : Membrane Air Dryer
    Membrane Air Dryer
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서

    ● Installed in the end of the compressed air system, it can produce 20℃ dew-point high quality compressed air

    ● You can install it on the wall easily with bracket

    ● No electric consumption, no power, no noise

    ● Environmentally friendly

    ● Beautiful appearance with aluminum anodized housing

    ● Easily control the purge air with needle valve (0% ~)

    ● Upon request for customer-engineered products

    ● You can use it permanently if the oil is removed beforehand properly

    Inlet pressure 7 kg/cm2

    Inlet temperature

    25℃ ~ 30℃
    Design pressure 9.9 kg/cm2 Ambient temperature -
    Differential pressure 0.2 kg/cm2 Dew Point -40℃
     
    Model
    Connection
    Applicable compressor
    Flow rate
     
    Dimension [mm,kg]
    PMD-
    [inch]
    [HP]
    [ℓ/min]
    Width
    Height
    Weight
    135
    15A
    1
    135
    230
    75

    1.0

    240
    15A
    2
    240
    370
    75
    1.3
    370
    15A
    3
    370
    480
    75
    1.6
    600
    15A
    5
    600
    600
    75
    2.0
     

    NOTE
    1. The specification can be changed without notice to improve the products
    2. Bigger capacity can be supplied upon request (Package)

  • HYA : After Cooler After-cooler
    After-cooler HYA : After Cooler

    ● The heat transfer coefficient and durability is nice because the adhesion between cooper tube and fin is good ● IP54 class axial fan is applied ● Upon request for customer-engineered products    · Various control devices and electrical contact are available    · Various electrical

    기술자료 브로슈어 상세보기
    HYA : After Cooler
    (Air Cooled , Water Cooled type)
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서

    ● The heat transfer coefficient and durability is nice because the adhesion between cooper tube and fin is good

    ● IP54 class axial fan is applied

    ● Upon request for customer-engineered products
       · Various control devices and electrical contact are available
       · Various electrical

    Differential pressure 0.3 kgf/cm2

    Max working pressure

    14.0 kgf/cm2
    Ambient temperature 2℃ ~ 40℃ Max ambient temperature 80℃
     
          Air-cooled
    Model
    HYA -
     
    Applicable
    compressor
    [HP]

    Flow rate
    [Nm³/min]

    Connection
    Fan motor
    Dimension [mm]
    Weight
    [kg]
    Diameter
    [mm]
    Width
    Leight
    Height
    20A 7.5 1.0 25A 230 x 1 230 500 590 15
    25A 25.0 3.2 25A 230 x 1 230 500 590 16
    40A 35.0 5.1 25A 300 x 1 300 600 700 23
    50A 50.0 7.8 40A 250 x 2 370 900 710 40
    80A 75.0 12.7 50A 300 x 2 370 1,030 810 46
    100A 130.0 17.5 50A 350 x 2 400 1,160 825 55
    150A 170.0 28.0 80A 450 x 2 460 1,690 1,095 180
    200A 200.0 41.0 100A 500 x 2 425 1,780 1,245 210
    300A 300.0 52.0 100A 550 x 2 480 1,880 1,360 230
    400A 400.0 65.0 125A 450 x 4 470 1,830 1,615 300
    500A 500.0 75.0 150A 500 x 4 475 1,975 1,685 350
    600A 600.0 95.0 150A 550 x 4 530 2,075 1,840 370
     
        Water-cooled
    Model
    HYA -
    냉각수량
    /min

    Flow rate
    [Nm³/min]

    전열면적
    Dimension [mm]
    Weight
    [kg]
    A
    B
    C
    100w 55 18 2.1 1,280 1,080 155 112
    200w 105 30 3.1 1,450 1,230 155 121
    300w 155 36 5.1 1,780 1,580 168 163
    400w 210 42 5.9 1,900 1,700 180 233
    500w 270 60 6.3 2,000 1,750 180 253
    600w 320 90 11.7 2,100 1,850 210 410
     

    NOTE
    1. Max inlet temperature is 80℃.
    2. Bigger capacity can be supplied upon request.
    3, The specification can be changed without notice to improve the products.

  • HYF : Air Filter Compressed air filter
    Compressed air filter HYF : Air Filter

    ● 압축공기에 포함된 불순물 및 부식성 가스 등의 효과적인 제거 ● The float and drain valve of the compressed air filter can remove the condensate effectively    · The models smaller than HYF-20 and HYF-20 : Built-in float type    · The models bigger than HYF-25 and HYF-25 : HAD-20 drain valve is equipped. ● Easy to replace the filter element. ● 40㎛, 5㎛ : Particulate filter, 1ppm, 0.1ppm, 0.01ppm : Coalescent filter ● Upon request for customer-engineered products

    기술자료 브로슈어 상세보기
    HYF : Air Filter
    Air Filter
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서
    ● 압축공기에 포함된 불순물 및 부식성 가스 등의 효과적인 제거
    ● The float and drain valve of the compressed air filter can remove the condensate effectively
       · The models smaller than HYF-20 and HYF-20 : Built-in float type
       · The models bigger than HYF-25 and HYF-25 : HAD-20 drain valve is equipped.
    ● Easy to replace the filter element.
    ● 40㎛, 5㎛ : Particulate filter, 1ppm, 0.1ppm, 0.01ppm : Coalescent filter
    ● Upon request for customer-engineered products
    Differential pressure 0.2 kg/cm2

    Max. working pressure

    50A 이하 14.0 kg/cm2
    65A 이상  9.9 kg/cm2
    적정 입구온도 25℃ 최고 입구온도 80℃
     
    Model
    HYF -
    Connection
    Flow rate [Nm³/min]
    Element
    amount
    Dimension [mm, kg]
    40
    μ
    5
    μ
    1
    ppm
    0.1  0.01
    0.01F ppm
    Width
    Leight
    Weight
    15A 15A 2.2 1.8 1.2 1.0 1 95 300 2
    20A 20A 5.7 3.5 2.8 1.9 1 110 310 2
    25A 25A 8.0 5.7 5.0 3.4 1 110 432 2
    40A 40A 17.0 14.0 11.0 10.0 1 144 700 12
    50A 50A 29.0 25.0 22.0 14.0 1 185 925 21
    65A 65A 58.0 49.0 48.0 28.0 2 550 1105 88
    80A 80A 88.0 73.0 72.0 42.0 3 550 1105 103
    100A 100A 139.0 120.0 110.0 70.0 5 600 1135 120
    125A 125A 162.0 145.0 132.0 84.0 6 650 1968 145
    150A 150A 282.0 221.0 176.0 112.0 8 650 1968 185
    200A 200A 447.0 331.0 308.0 196.0 11 1000 2367 250
    250A 250A 733.0 555.0 528.0 330.0 19 1200 2745 325
    300A 300A 1130.0 850.0 792.0 504.0 30 1400 2745 500
     

    NOTE
    1. The specification can be changed without notice to improve the products.
    2. 스테인레스 스틸 필터도 제작 가능합니다.
    3. 엘리먼트 모델을 선정하실 때에는 필터의 모델 기호인 HYF를 HYE로 사용해주시면 됩니다.

  • Drain Water chiller/Oil-water separator/Drain value
    Water chiller/Oil-water separator/Drain value Drain :

    산업현장에서 사용되는 압축공기를 생산하기 위해 사용되는 공기압축기에서는 일반 공기를 높은 압력으로 변화시키변서 상대습도와 온도가 매우 올라가게 됩니다. 이 온도가 배관라인이나 기타 장비로 들어가면서 공기 사용온도로 맞춰지게 되면 이에 따라 과다한 양의 응축수가 발생됩니다. 또한 공기압축기 내부에서 대기중의 공기가 ROTOR(마찰열 감소를 위해 OIL이 들어감)을 통과하며 유분이 함유되기도 하여, 응축수나 이러한 유분을 걸러주는 장비가 매우 절실합니다.   압축공기내의 응축수를 완전히 배출시키어 배관에 함께 연결된 에어 드라이어나 리시버 탱크, 생산설비 등에 기기 고장의 확률을 낮추고 기기 수명을 높이는 드레인이 필수적입니다.  용도나 처리 유량에 따라 적절한 드레인을 선정하시기 바랍니다

    기술자료 브로슈어 상세보기
    Drain
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서
    산업현장에서 사용되는 압축공기를 생산하기 위해 사용되는 공기압축기에서는 일반 공기를 높은 압력으로 변화시키변서 상대습도와 온도가 매우 올라가게 됩니다. 이 온도가 배관라인이나 기타 장비로 들어가면서 공기 사용온도로 맞춰지게 되면 이에 따라 과다한 양의 응축수가 발생됩니다. 또한 공기압축기 내부에서 대기중의 공기가 ROTOR(마찰열 감소를 위해 OIL이 들어감)을 통과하며 유분이 함유되기도 하여, 응축수나 이러한 유분을 걸러주는 장비가 매우 절실합니다.   압축공기내의 응축수를 완전히 배출시키어 배관에 함께 연결된 에어 드라이어나 리시버 탱크, 생산설비 등에 기기 고장의 확률을 낮추고 기기 수명을 높이는 드레인이 필수적입니다.  용도나 처리 유량에 따라 적절한 드레인을 선정하시기 바랍니다
    내 문서
    차압 0.2 kg/cm2

    최대 사용압력

    50A 이하 14.0 kg/cm2
    65A 이상  9.9 kg/cm2
    적정 입구온도 25℃ 최고 입구온도 80℃
     
    Model
    HYF -
    접속
    구경
    처리유량 [Nm³/min]
    엘리먼트
    갯수
    크기 [mm, kg]
    40
    μ
    5
    μ
    1
    ppm
    0.1  0.01
    0.01F ppm
    가로
    세로
    무게
    15A 15A 2.2 1.8 1.2 1.0 1 95 300 2
    20A 20A 5.7 3.5 2.8 1.9 1 110 310 2
    25A 25A 8.0 5.7 5.0 3.4 1 110 432 2
    40A 40A 17.0 14.0 11.0 10.0 1 144 700 12
    50A 50A 29.0 25.0 22.0 14.0 1 185 925 21
    65A 65A 58.0 49.0 48.0 28.0 2 550 1105 88
    80A 80A 88.0 73.0 72.0 42.0 3 550 1105 103
    100A 100A 139.0 120.0 110.0 70.0 5 600 1135 120
    125A 125A 162.0 145.0 132.0 84.0 6 650 1968 145
    150A 150A 282.0 221.0 176.0 112.0 8 650 1968 185
    200A 200A 447.0 331.0 308.0 196.0 11 1000 2367 250
    250A 250A 733.0 555.0 528.0 330.0 19 1200 2745 325
    300A 300A 1130.0 850.0 792.0 504.0 30 1400 2745 500
     

    NOTE
    1. 사양은 품질 개선을 위하여 예고없이 변경될 수 있습니다.
    2. 스테인레스 스틸 필터도 제작 가능합니다.
    3. 엘리먼트 모델을 선정하실 때에는 필터의 모델 기호인 HYF를 HYE로 사용해주시면 됩니다.

  • POS : Oil - Water Separator Water chiller/Oil-water separator/Drain value
    Water chiller/Oil-water separator/Drain value POS : Oil - Water Separator

    ● 세계적인 특허로 신뢰도가 높고, 꾸준한 응축수 처리 가능 ● 응축수 배출시 정화되지 않은 상태로 함께 배출되는 오일의 분리 ● 전원 연결이 필요없으며, 설치가 간편 ● 주 1회 정도의 검사를 통한 낮은 유지 관리비 ● 간단한 시약 테스트를 통한 필터의 교환 시기 판단 가능 ● 여러 각도에서도 연결이 가능하도록 설계 (최고 4개의 응축수 유입라인으로 연결 가능) ● 오일의 무단 방출, 필터로의 재역류 현상 등의 방지 ● 관리가 용이한 Level Indicator와 샘플 수시 채취로 필터의 청결도 감시 ● 작업 환경에 맞는특별 사양 제작    · 결빙 방지를 위한 Heating 장치 추가    · Level Indicator의 전자 Alarm Sensor를 통한 컨트롤 시스템

    기술자료 브로슈어 상세보기
    POS : Oil - Water Separator
    Oil - Water Separator
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서

    ● 세계적인 특허로 신뢰도가 높고, 꾸준한 응축수 처리 가능

    ● 응축수 배출시 정화되지 않은 상태로 함께 배출되는 오일의 분리

    ● 전원 연결이 필요없으며, 설치가 간편

    ● 주 1회 정도의 검사를 통한 낮은 유지 관리비

    ● 간단한 시약 테스트를 통한 필터의 교환 시기 판단 가능

    ● 여러 각도에서도 연결이 가능하도록 설계 (최고 4개의 응축수 유입라인으로 연결 가능)

    ● 오일의 무단 방출, 필터로의 재역류 현상 등의 방지

    ● 관리가 용이한 Level Indicator와 샘플 수시 채취로 필터의 청결도 감시

    ● 작업 환경에 맞는특별 사양 제작
       · 결빙 방지를 위한 Heating 장치 추가
       · Level Indicator의 전자 Alarm Sensor를 통한 컨트롤 시스템

    Model
    스크류 공기압축기
    피스톤 공기압축기
    무게
    오일 종류[N㎥/min] 오일 종류[N㎥/min]
    POS-
    터빈
    VDL
    VCL
    합성
    터빈
    기타
    [kg]
    1
    1.5
    1.3
    1.0
    0.3~1.0
    1.0
    0.4~0.7
    4
    2
    4.0
    3.5
    2.5
    1.2~2.5
    2.0
    0.7~1.4
    10
    4
    8.5
    7.0
    5.5
    2.3~5.5
    4.4
    1.4~3.3
    24
    5R
    16.5
    14.5
    11.0
    5.5~11.0
    8.8
    3.3~6.5
    30
    6
    33.0
    30.0
    22.0
    11.0~22.0
    22.0
    6.5~16.8
    40
    8
    105.0
    90.0
    70.0
    25.0~70.0
    70.0
    17.0~52.0
    90

    NOTE
    1. 상기 사양은 품질 개선을 위하여 예고없이 변경될 수 있습니다.

  • HYC : Water Chiller Water chiller/Oil-water separator/Drain value
    Water chiller/Oil-water separator/Drain value HYC : Water Chiller

    ● 1차 산업부터 최첨단 반도체 산업까지 온도 변화가 필요한 모든 산업현장에서 사용 가능 ● DX 코일이 내장되어 냉각 성능 향상 (30%) ● 소음과 진동이 없는 Grundfoss Pump 및 Goulds, Calpeda Pump 장착 ● 신뢰성이 우수하고 저소음, 저진동 실현 ● 특별 고안된 칠러 전용 게이지 부착 ● 에어컨 PB 소재 채택으로 내부식성과 내열성 강화로 부식 및 동파 방지 ● 전자식 자동온도조절기(Digital Thermo Controller) 채택으로 정확한 온도유지 및 광범위한 사용온도 조정 가능 ● 작업 환경에 맞는특별 사양 제작   · 기타 제어 장치 추가 및 접점 인출    · R-22 대체 냉매인 R-404A용 드라이어    · 다양한 전기사양 가능     · 분리형 type

    기술자료 브로슈어 상세보기
    HYC : Water Chiller
    (Air Cooled type)
    기술자료 브로슈어
    상세보기
    제품설명 제품사양서

    ● 1차 산업부터 최첨단 반도체 산업까지 온도 변화가 필요한 모든 산업현장에서 사용 가능

    ● DX 코일이 내장되어 냉각 성능 향상 (30%)

    ● 소음과 진동이 없는 Grundfoss Pump 및 Goulds, Calpeda Pump 장착

    ● 신뢰성이 우수하고 저소음, 저진동 실현

    ● 특별 고안된 칠러 전용 게이지 부착

    ● 에어컨 PB 소재 채택으로 내부식성과 내열성 강화로 부식 및 동파 방지

    ● 전자식 자동온도조절기(Digital Thermo Controller) 채택으로 정확한 온도유지 및 광범위한 사용온도 조정 가능

    ● 작업 환경에 맞는특별 사양 제작
      · 기타 제어 장치 추가 및 접점 인출
       · R-22 대체 냉매인 R-404A용 드라이어
       · 다양한 전기사양 가능 
       · 분리형 type

    Model 7 kg/cm2

    입구온도

    5℃ ~ 30℃
    설계압력 9.9 kg/cm2 주위온도 25℃
    차압 0.2 kg/cm2 노점 4℃ ~ 10℃

    Model 접속
    구경
    탱크용량 냉동기
    처리유량
    펌프
    처리유량
    크기 [mm]
    HYC- [ℓ] [Kcal/hr] [Kw] [ℓ/min] 가로 세로 높이
    1A
    15A
    32
    3,024
    0.75
    10~20
    530
    935
    800
    2A
    20A
    66
    6,048
    1.5
    16~70
    600
    1155
    1100
    3A
    20A
    66
    9,072
    2.25
    16~70
    600
    1155
    1100
    5A
    25A
    117
    15,120
    3.75
    16~70
    680
    1300
    1200
    8A
    32A
    154
    21,168
    7.25
    41.7~150
    750
    1350
    1400
    10A
    40A
    192
    30,240
    7.5
    41.7~150
    800
    1600
    1700
    15A
    40A
    225
    45,360
    11.25
    100~200
    1000
    1835
    1800
    20A
    50A
    300
    60,480
    15.0
    200~300
    1100
    2200
    2100
    30A
    50A
    430
    90,720
    22.5
    200~300
    1100
    2550
    2100

    NOTE
    1. 적정 사용온도는 5℃ ~ 30℃, 주위 온도는 30℃입니다.
    2. 사용 유체는 물, 증류수, 절삭유, 기타 유체입니다.
    3. 냉매는 R-22, R-404, R-407을 사용합니다.
    4. 사양에서 제시된 이상의 대형 기종도 가능합니다.